Too much ash may indicate that the pellet stove's feed rate is too high. Once the air has started flowing through the stove, a pressure switch commonly called a vacuum switch either senses this pressure and closes the circuit to the feed motor and igniter, or senses back pressure and opens the circuit to the feed motor and igniter. There could also be a loss of draft pressure. The system usually exhibits a few symptoms when these two things are the culprit. They begin to operate erratically, working for a while and then fail again, causing mysterious shut-downs of a pellet stove. Ashley pellet stove error codes have different meanings. Fuel is having a hard time feeding into the burnpot. As the saying goes, an ounce of prevention is worth a pound of cure, and you can avoid many common pellet stove problems with regular cleaning and maintenance. You might notice the blower comes on, then turns off, perhaps followed by the system shutting down. JavaScript is disabled. If this doesn't work, try #2. you can jump the switch by using a wire or paperclip. Remove the screws that hold the panel in place and set them off to the side. Oil or apply some grease to allow the motor to move easily. All of Ashley Hearth stoves including the AP130 are EPA-certified. Ashley Hearth AWC21R - The Best Iron Wood Stove. Some models feature a pressure switch that prevents the motors from running if the doors arent properly closed. Like a soiled burnpot, a dirty exhaust system causes numerous issues, including poor burning, and fires that periodically die. Ashley Hearth is a brand owned by the USSC (United States Stove Company). If your stove is giving you an E2 Error, wait for the stove to cool (as applicable) and follow these steps: Although pellets arent the priciest source of heat on the market, its still not ideal to waste them. How To Do So Safely. If your stove will power on but will not feed pellets at startup, or the stove will not enter into the startup procedure from the get-go, here are some things to check. If the stove never detects a temperature high enough for proof of fire, the stove will shut off when the shutdown timer expires. Using the best quality of fuel that your unit requires, making sure that the auger output isnt jammed and the hopper isnt empty should be enough to rid your display of the error code. Refill the. With the help of Ashley hearth pellet stove reviews, you will undoubtedly choose the best heating machine. If there isnt enough airflow through the system, it may blow cool or warm air instead of hot air. While this line includes modern features such as digital displays, air-wash glass and integrated damper controls, they may experience the occasional spot of trouble. The igniter uses electricity to light itself, saving you the hassle of lighting the stove yourself. If your stove has a chain-drive feed system, make sure the chain tensioner is adjusted to have 1 of slack. Everything seems to be okay there are pellets in the hopper, the stove is plugged in, and there are no apparent issues. Usually, if a pellet stove is using a thermocouple or RTD probe to measure the stove temperature, and it's looking for the lowest heat value to turn off, its not going to be a faulty sensor. Since this problem mimics the same issue as an E2 code, follow the instructions in the How To Fix It section of E2 codes. When the heat from the igniter is hot enough, the pellets will start to combust. Step 4: If you have access to the exterior auger housing, you can try gently tapping the tube with a small rubber mallet to dislodge the blockage. They can be so dirty that air isn't able to flow through the vent system fast enough. Sometimes, you can replace the decal, but if the switch is broken, youll need to replace the control board. All Right Reserved by FIREPLACEHUBS. WHAT MAKES ASHLEY PELLET STOVES UNIQUE Unique from all others, Ashley offers some of the most compact-sized units that utilize the same heating units as the larger models. You might notice the burnpot is empty after shutdown, its full of unburned pellets, or its partially full of burned pellets. Ashley Hearth is a brand under the United States Stove Company (USSC). COPYRIGHT 2023. Thus, it can provide your desired warmth despite its compact size. The original was tagged at 4.1rpm ccw. The ESP probe in the exhaust is looking for 95F to cut power to the stove. To solve error code 1, you can start by making sure there is enough ventilation in the room. Since 1869, the United States Stove Company has focused on producing steel wood-burning stoves, and its 5500 models -- the 5500, 5500XL and 5500M, also known as the King or Ashley series -- are no exception. Installation Tools, Equipment, & Hardware. Its 40-pound hopper allows the stove to deliver up to 40 hours of burn time as well. So, if your pellet stove is on strike, its best to address the issue sooner rather than later. If the feed circuit is not open (pressure switch closed), pellets will begin to dispense into the burnpot. 40 Reviews . Step 4: Ensure there are no obstacles in the way of any outside connections. The burnpot is empty after shutdown, 2. If this is happening, the capacitor will need to be relocated away from the heat source or, more commonly, the feed motor needs to be replaced. The pellet stove is our only source of heat by choice. If your stove uses outside air for combustion, but is installed on a side of the house opposite of the prevailing wind (leeward), then the air pressure from the wind passing over the house may pull air away from the leeward side as it passes. Use amazon messager to contact seller. A 40-pound bag of pellet fuel may offer solid heat for up to 24 hours. They are called snap disc switch, high limit temperature sensor, thermo-disc, thermal limit and much more. Pellet stoves can last up to ten years when used properly. Some things can cause this, including damp pellets, poor-quality pellets, and a too-fast feed rate. If your stove's venting is a straight shot out of your house, a gust of wind can sometimes create a "puff" in the stove, blowing the fire out. Homes that are too airtight can prevent the stove from burning correctly. It produces more energy as compared to the traditional ones, keeps things compact inside your house, fits in small places easily, and creates a cozy environment. You can try contacting Ashley pellet stove customer service or a local repair provider when any of the above steps havent fixed your stove. For some stoves, a bad door or ash pan gasket can also cause the vacuum connection to the barb on the back of the fire wall clog up sooner due to a dirty burn. These cracks can form around the heads of the buttons under the decal. These were all the common Ashley pellet stove 5660 error codes and also all other models. Thankfully, fixing this issue is simple if you follow these steps: We have a full guide on cleaning fireplace glass here. Refill the stove's hopper if the 5500's fire goes out or if it shuts down. Generally, this happens when you leave the stove plugged in year-round and have a power surge at some point during the off-season. Disclosure statement. Youll know you have a jam when you hear the auger motor trying to turn and no pellets are falling into the firepot. The Five Biggest Sports Clubs In The World, Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix], Rheem Tankless Water Heater Code P1 [Why+ How To Fix]. Also how I set it up through a wall and i show thermostat hookup. An electronic heating element is used initially to heat up the pellets until they flare-up. If this is broken, it might be stuck in the closed position. Error codes for this are usually #4 or #4 and #5. Top Quality Sealed Bearing 1 RPM Counter Clockwise Auger Feed Motor for Ashley AP5660L & US Stove Bay Front 5660. Customers will have to present a proof of purchase to claim the service. Check the heat sensor. Check your owners manual if youre unsure what the blinks mean. The possible reasons why your Ashley pellet stove is not feeding pellets are-. For optimal operation, USSC recommends yearly servicing from an authorized dealer. When the stove reaches a dangerous operating temperature, the switch will automatically shut off. Top Best Ashley Pellet Stove Problems Comparison 2022 Bestseller No. Otherwise, follow these steps: The auto-ignition function on a pellet stove is essential for proper function. Or, it could point to a blocked flue. If the vent extends straight out of your house, a gust of wind may cause a burst of air to move down the pipe, snuffing the fire out. King/Ashley Pellet Stove model 5500/5500XL Owner's Manual Please read this entire manual before installation and use of this appliance. Your email address will not be published. Wiseway Non Electric Gravity Fed Pellet Stove Review, In-depth Review of Englander Pellet Stove. Generally, this would only happen on a very windy day. Step 1.1 - Unplug the stove and remove the access panels to the components. Wow I do not think you want the rest of my thoughts. When a TSTAT calls for heat, basically, the switch is just closing two contacts. 162.0 3. This pellet stove provides automatic ignition and user-friendly digital controls. Check the system for dirt, dust, and grime. Another common problem with the auger is that it might have a faulty motor. So now lets look at the reasons that might cause error code 2. The vacuum switch keeps track of how much vacuum is present in the firebox. First, the pellets might be damp. To request service, call USSC. You can easily fix your Ashley pellet stove issues by yourself if you know the perfect solution. Make sure the viewing door is properly closed and sealed. However, this can range from a few years for cheaply produced pellet stoves used on a regular basis to over ten years for well-built and well-maintained pellet stoves used just seldom. Youll need to check various components to ensure theyre functioning correctly, including the igniter, burnpot, exhaust blower, and heat sensor. This happens in auto-ignition-equipped models, as they monitor themselves during the startup sequence. Yes, you should be able to. 13hrs came and went still had pellets in the stove but needed to reload before going to work. Try lowering the heat setting or closing the draft/damper. On the other side of the air chamber, a speed blower collects heat and spreads heat throughout the room. You can try greasing the bearings to make everything run smoothly. cap. Your email address will not be published. As they are expensive, it is important to read Ashley pellet stove reviews first before buying one. Are your pellet stoves guaranteed safe to use? COPYRIGHT 2023. The stove works through a software-driven control board. Pellet Stove Burning Poorly Ashley Pellet Stove Error Codes [7 Easy Solutions], 4. Usually pressure switches do not fail. Ashley Pellet Stove E6 Error Code The pellet stove may be fine, but the auger itself may be jammed with something foreign. Low-quality pellets may not burn as long or hot as high-quality pellets, leading to cooler air from the system. A simple cleaning will fix this issue. If your pellet stove is running for 15 minutes, then shutting off leaving burn grate full of pellets, c heck for a defective igniter (Figure 1). The consent submitted will only be used for data processing originating from this website. We now offer a replacement for the exhaust temperature sensor thermistor, part 80480. The heat and exhaust exit the stove through one side of the air chambers. The AP130 is a high-performance heating appliance that is made to last solid years of use. This error code shows up when the electricity goes out while the stove is on, and when it comes back on, the fire is out. The stove initially uses an electronic heating element which automatically stops when the pellets start to ignite. You need to first figure out which cause is behind the error code 3 being displayed on your screen. Clean the debris and grease accumulated if needed. If theres a considerable dust accumulation, remove it from the system. Check the venting connections on your pellet stove. How to adjust your pellet stove to fine tune your burn rate. It includes an exhaust blower that helps to get rid of smoke spillage. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Generally, when this happens, itll give a code, usually E2. Ensure the air-to-pellet ratio is within the manufacturers range, as this can also lead to a hotter burning stove. Use pliers to fix the motor properly. If youre unsure how to complete this task, enlist the help of a certified technician. Airflow can also be hampered by a non-spinning combustion blower or a malfunctioning control board. Adjust the feed rate. For excess ash, use an ash vacuum, if available. Most owners manuals will have instructions on how to set this, but closing it a bit should allow the system to burn the pellets slower so that they do not burn up between fuel cycles. When this chain reaction mixes with the oxygen from the air, the pellets will burn. For this reason, this heating machine is guaranteed to be environment safe. Clean the system as necessary. Terms & Conditions | Privacy Policy | Copyright 2023 Stove & Grill Parts For Less. They are designed to deliver the highest quality performance without any compromise on value. Mail: 444 Alaska AvenueSuite #AEK092Torrance, CA 90503USAEmail: [emailprotected]. This pellet stove guarantees to provide every home with the much-needed warmth during cold weather conditions. Clear exhaust screens of ash using an ash vacuum cleaner; don't use a standard shop vac for this job, as it may release particles of ash into the surrounding air. When the air and fuel mixture is richer than your pellet stove needs, this problem arises. A vacuum error can occur if an upgraded high speed blower is installed in a Magnum BabyCountryside stove. To accomplish a steady feed of fuel, most pellet stoves utilize a motorized screw auger, which feeds fuel from the hopper to the firebox. The Ashley Hearth AP5710 is a small-bodied pellet stove perfect for smaller spaces. Additionally, it has a classic cast steel construction that is reliable and durable. Try opening a window (only a tiny amount) in the room where the stove is to see if this remedies the problem. If there isnt residual fuel in the burnpot, a few things could happen. While every stove is different, the following are the most typical reasons for your pellet stove not working: You can take the following measures to stop your stove from shutting down on you. Every pellet stove has a sensor to detect proof of fire. If you have a clogged vent or a significant leak. Problems such as this, a faulty circuit board and other more complex mechanical troubles require service from authorized technicians. When people overfill the hopper, sometimes the pellets being crammed into a confined space can break or dislodge a wire from the underside of the exposed wire connections in the switch.